US Water 300 GPD Floor-Mount Light Commercial Economy RO System with 20” Pre-Filters

Sku: 220-USCRO-300FR

Ask a question (5)
Regular Price: $1,630.00
Sale Price: $978.00
In Stock

* Required Fields

To buy, select Add A Tank

Choose from option(s) above

Additional payment option(s)

Overweight and/or Oversized shipping fee per qty applied at checkout.

US WATER Light Commercial Economy 300 GPD RO with enhanced chlorine removal – 20” Filter Housings

You may also need
Check items to add to this order or select all and then click ADD TO CART button

view less
Product Description

Product Description

US Water RO Logo

 

US Water Economy 300 GPD Economy RO System

Do you need a light duty commercial reverse osmosis system that can deliver up to 300 GPD with water that has TDS levels of up to 1,500, but also don’t want to break the bank? Then the USCRO-300DM is simply the best solution. It features a frame-mount that can be either mounted on the wall or used as a floor mount system.

This systems comes four ways:

  1. Without a Tank
  2. With a 4.5 Gallon Metal Tank
  3. With a 14 Gallon Metal  Tank
  4. With a 20 Gallon Metal Tank

Benefits

 

  • Corrosion Resistant Frame Will not Rust 
  • Pressure Gauge for Monitoring Pre-filter Pressure 
  • Lightweight Compact Space Saving Design 
  • Pre-Plumbed, Wired & Assembled * Plug & Play 
  • Components Easily Accessible for Service 
  • CE Compliant 
  • 1-Year Limited Warranty

 

Features

 

  • White Powder Coated Aluminum Frame 
  • Capable of Floor or Wall Mount 
  • 5 Micron Sediment Pre-Filter Protects the System 
  • 10 Micron Carbon Block Pre-Filter Removes Chlorine 
  • 10 Micron Carbon Block Pre-Filter Removes Additional Chlorine
  • 300 GPD TFC Reverse Osmosis Membrane 
  • Single AQUATROL Booster Pump

 

Specifications

Design

Configuration

Single Pass

Feed Water Source

TDS < 1500

Standard Recovery Rate

33%

Rejection and Flow Rates

Nominal Salt Rejection %

97.5

Permeate Flow* gpm (lpm)

0.21 (0.79)

Concentrate Flow gpm (lpm)

0.21 (0.79)

Connections

Feed inch

3/8 Tube

Permeate inch

3/8 Tube

Concentrate inch

1/4 Tube

Membranes

Membranes(s) Per Vessel

1

Membrane Quantity

1

Membrane Size

3 x 14

Vessels

Vessel Array

1

Vessel Quantity

1

Pumps

Pump Type

Aquatrol

Electrical**

Standard Voltage

110V 60Hz 1 PH

Voltage Amp Draw

1.0

Systems Dimensions ***

L x W x H inch 

11 x 18 x 32

Weight lb.

60

Operating Limits

Maximum Feed Temperature °F (°C)

85 (29.00)

Minimum Feed Temperature °F (°C)

40 (4.44)

Maximum Ambient Temperature °F (°C)

120 (48.89)

Minimum Ambient Temperature °F (°C)

40 (4.44)

Maximum Feed Pressure psi

85

Minimum Feed Pressure psi

45

Maximum Operating Pressure psi

120

Maximum SDI Rating SDI

< 3

Maximum Free Chlorine ppm

0

Maximum TDS ppm

1500

Maximum Hardness gpg

1

Maximum pH (Continuous)

11

Minimum pH (Continuous)

3

Maximum Turbidity NTU

1

*Product Flow rates are based on equipment test parameters.
**Call for other voltage options.
***Does not include operating space requirements.

Test Parameters: *550 TDS Filtered (5 Micron), De-Chlorinated, Municipal Feed Water, 100 psi (6.89 bar) Operating Pressure, 77 Degrees F (25 Degrees C), Recovery as stated, 7.0 pH. Data taken after 60 minutes of operation. Scale prevention measures must be taken to prolong membrane life.

Low temperatures and high feed water TDS levels will significantly affect system’s production capabilities. Performance projections should be run for individual applications which do not meet or exceed minimum and maximum operating limits.

view less
-
Additional Information

Additional Information

Availability In Stock
System Type Wall Mount
Manufacturer US Water Systems
Warranty 1 Year Manufacturer's Warranty

view less
-
Literature

Videos
view less
-

Videos

Sorry No Videos Available

view less
-
Ratings & Reviews

Ratings & Reviews

view less
-
Product FAQs

Product FAQs

 

Ask a Question

  • My source water runs approximately 500 ppm tds. I would run this unit after my softener. What would be the approximate tds in ppm of the product water of this unit? I do not see that information listed anywhere but perhaps I missed it. Thank you for your time.

    What the TDS would be depends what you are doing with it, whether you are using an atmospheric tank or a bladder tank and how much you use it.

    The quality could be as low as 20 or as high as 50 depending upon several factors.

  • What connections do I need to connect a hose to the 20 gallon storage tank so that I can fill bottles? Do you sell those products and/or do you recommend a certain product? Will be purchasing within the next few days and need to make sure we have a way to connect a hose.

    That would depend what size you need.  It could be 3/8”, ½” or ¾”. Please let us know what you want and we can provide it.

  • What can I expect (in gallons) for total output of this system before filters need replaced?

    That would be totally dependent upon what is in your water, and what kind of pre-treatment you may use.  To answer the question I would need to see a detailed water analysis.  I have seen the filters last two years or plug up in two days, depending upon your water!

  • Is there a system for small home use that would provide enough volume at sinks (2) to wash your face, etc.?

    We have systems for any size.  We even do whole house RO, but you wash your face with hot and cold water.  The hot water would also have to be treated for the whole house, unless you have a small water heater for washing your face.

  • How much water line pressure will your 300 gpd RO system handle? Do the 300- and 600 gpd systems use the same filters? What determines the difference between the two? We currently have a conventional water softener (uses salt) which has failed; will I need to hire a plumber to install your RO system? Why would I want to buy a tank with one of your systems?
    • How much pressure – 80-100 PSI
    • Same filters – Yes
    • The difference – 300 more gallons a day
    • If your water is hard, you will still need to use and anti-scalant or a softener before the RO/
    • Many people install it without a plumber.  In fact, we recommend you don’t hire a plumber.
    • Why would you want to buy a tank?  Are you using it for the whole house?  You do realize that a 300 GPD system makes less than .02 Gallons Per Minute?